YJV62-26/35kV HV power cable

This product according to GB/T12706-2008 "rated voltage 35kV copper core, aluminum core plastic insulated power cable" standard production, but also according to user needs according to the International Electrotechnical Commission recommend standards IEC, British standards, German standards and American standards production.

Key words:

Email:

Product Description

1. product standards

This product according to GB/T12706-2008 "rated voltage 35kV copper core, aluminum core plastic insulated power cable" standard production, but also according to user needs according to the International Electrotechnical Commission recommend standards IEC, British standards, German standards and American standards production.

2. scope of application

This product is suitable for power frequency rated voltage 35kV and below distribution network or industrial equipment in the use of fixed laying.

3. working temperature and laying conditions

1. Power frequency rated voltage U0/U 3.6/6, 6/6, 6/10, 8.7/10, 8.7/15, 12/20, 18/20, 18/30, 21/35, 26/35kV.
2. The maximum allowable long-term temperature of the cable conductor shall not exceed 90 ℃.
3. The maximum temperature of the cable conductor shall not exceed 250 ℃ during short circuit (the longest time shall not exceed 5S).
* Laying on the ground
4. The ambient temperature during cable laying shall not be lower than 0 ℃.
5. Cable bending radius:
Single-core cable: 20(D + d)± 5%
Three-core cable: 15(D + d)± 5%






4. cable model

Model Name Scope of application
YJV Copper conductor XLPE insulated PVC sheathed power cable Indoor tunnels and cable trenches and other places, can not withstand mechanical external forces, single-core cables are not allowed to be laid in the magnetic pipeline.
YJLV Aluminum conductor XLPE insulated PVC sheathed power cable
YJY Copper conductor XLPE insulated PE sheathed power cable
YJLY Aluminum conductor XLPE insulated PE sheathed power cable
YJV22 Copper conductor XLPE insulated steel tape armored PVC sheathed power cable Indoor, tunnel, cable trench or directly buried underground, can withstand certain mechanical external force, but can not withstand large tension.
YJLV22 Aluminum conductor XLPE insulated steel tape armored PVC sheathed power cable
YJV23 Copper conductor XLPE insulated steel tape armored PE sheathed power cable
YJLV23 Aluminum conductor XLPE insulated steel tape armored PE outer sheath power cable
YJV32 Copper conductor XLPE insulated fine steel wire armored PVC sheathed power cable Indoor, tunnel, cable trench or directly buried underground, able to withstand high-intensity mechanical external force and tension.

5. production scope

Model Number of cores Rated voltage kV
3.6/6 6/6 8.7/10 12/20 18/20 21/35 26/35
6/10 8.7/15 18/30
Nominal section of conductor ㎜ 2
YJV \ YJLV \ YJY \ YJLY 1 25-800 25-800 25-800 35-800 50-630 50-630 50-630
3 25-630 25-630 25-500 35-500 50-400 50-400 50-400
YJV22\YJLV22\YJY23\YJLY23 1 25-800 25-800 25-800 35-800 50-630 50-630 50-630
3 25-630 25-630 25-500 35-500 50-400 50-400 50-400
YJV32\YJLV32\YJY33\YJL\Y33 1 25-800 25-800 25-800 35-800 50-630 50-630 50-630
3 25-630 25-630 25-400 35-400 50-300 50-300 50-300
YJV32\YJLV32\YJV42\YJLV42 3 25-300 25-300 25-300 35-300 50-300 50-300 50-300

6. cable laying operation conditions

★Long-term maximum working temperature of cable conductor: 90 ℃.
★Ambient air temperature: 40 ℃.
★Soil temperature: 20 ℃.
★Soil thermal resistance coefficient: 1.0V.m/W.
★Buried depth: 0.8 m.
★Consider only one loop
★Single-core cables are laid horizontally, and the spacing is one cable outer diameter.





Product inquiry

We will contact you within one working day. Please pay attention to your email.